HPGe Spectrometer with Lead Shield

DESCRIPTION

Coaxial HPGe Detector with Lead Shield is used to measure the specific gamma radiation of radionuclides from various types of environmental objects such as rocks, minerals, sludge, slag, soil, plant, sediment and particulate matter in air and water.

Description

Application

Coaxial HPGe Detector with Lead Shield is used to measure the specific gamma radiation of radionuclides from various types of environmental objects such as rocks, minerals, sludge, slag, soil, plant, sediment and particulate matter in air and water.

Features

  • Adopting precision gamma-spectrometry methods
  • Radionuclide identification and determination of their specific activity
  • Low level of instrumental background
  • Low threshold for radionuclide detection
  • Separate and simultaneous measurement of activity of 100 radionuclides

COMPLETE SET

  • Detection Unit based on HPGe p-type coaxial detector with relative efficiency 10% – 160%
  • Lead Shield for lower back signal with a support
  • Liquid nitrogen level monitor (LN2 Monitor)
  • Multi Channel Analyzer
  • Emulation and analysis Software SpectraLineGP
  • Software package NuclideMasterPluss
  • Advanced software package EffMaker

SPECIFICATION

Parameter Value
Detection limit for Cs137 radionuclide specific activity, measurement time 1 hour, Bq/kg 0.5
Absolute sensitivity to gamma flux for 30% efficient detector, pulse/quantum 4.5 x 10-3
Instrumental background intensity for energy range from 40 KeV to 3 MeV, pulse/KeV x sec 5 x 10-4
Cs137 radionuclide specific activity measurement error for measurement time 1 hour, % 20
Shield thickness:
Lead wall, mm
Copper wall, mm
100
10
AC power supply:
Voltage, V
Frequency, Hz
230
50
Overall dimension, mm
Lead shield with detector
Spectrometric device
1300x580x480
300x180x80
Weight, kg
Lead shield with detector
Spectrometric device
465
2.8
Detection Unit (example)
Relative efficiency (with respect to 3’’ x 3’’ NaI detector and Co-60 source mounted 25 cm above the endcap) at 1.33 MeV g-photon, % > 30
Energy resolution with LN2, eV
at 122 keV
at 1.33 MeV
< 850
< 1850
Peak to Compton ratio at 1.33 MeV 60 : 1
Energy range of detector operation, keV 40 – 10000
Material of input window Al/Be/Carbon
Endcap diameter, mm 76
Preamplifier (built in detector capsule) with cooled FET and resistive feedback – Preamplifier power supply is ±12 V with 9 pin connector compatible with NIM standards – TTL signal to shut down the HV: – detector warm -0V; – detector cold: +5V – HV INHIBIT – BNC – Preamplifier and High voltage filter included – Automatic high-voltage shutdown to protect preamplifier input FET
2 LEDs on the separate cable end from preamplifier: – GREEN – detector is cooled down – RED – high count rate
Cable connectors: – 9 pin – PA Power supply; – 11 SHV – detector bias power supply; – BNC – signal output of detector
Indicator warns of excessive counting rate