Açıklama
Squidstat Solo Complete Setup (#SO-2X-CS)
- One Squidstat Solo (#SO-2X)
- Single-channel potentiostat/galvanostat
- Current range: ±100 mA max
- Voltage scan range: ±10 V
- Compatible with Windows, MacOS, and Ubuntu via the Squidstat User Interface software and Application Programming Interface
- Onboard memory (16 GB) automatically backs up all channel data for future recovery
- Multiple units can run simultaneously with other Squidstat models
- Made in USA
- One 1-meter Squidstat Basic Cell Cable (#CB-BC-1)
- One Power Source Cable (Country based)
- One USB Cable (#UB12-06-BLK)
- One Squidstat InkBoard with Grounding Strap (#IB-10-GS)
- Two Alligator Clips – 2 mm – Red (#BU-P5788-2)
- Two Alligator Clips – 2 mm – Black (#BU-P5788-0)
- One Alligator Clips – 2 mm – Green (#BU-P5788-5)
General Specifications
| Channels Per Unit | 1 |
| Operating Modes | Pot / Gal / ZRA |
| Cell Connections | 5 electrode |
| ADC/DAC Resolution | 16-bit resolution |
| Slew Rate (1 kΩ load) | 5 kV/s (-1 V to +1V) |
| Shortest DC data recording interval | 200 µs |
| Shortest DC data hardware sampling interval | 7.5 µs |
| Floating/Ground Mode | Both (Switchable) |
| Input Impedance | 10 Tera-Ω (typical) |
| Input Current | 10 pA (typical) |
| Data Backup Memory | 16 GB onboard |
| Dimension and Weight | 24 L x 17 W x 6 H cm, 1 kg |
| Channel Cable Length | 1 m |
| Computer Interface | 1 USB per unit |
| Temperature Operating Range | 0 to 40 ℃ |
| Min/Max Scan Rate | 300 μV/s minimum,
25 V/s maximum with 10 mV sampling
|
| Smallest Pulse Width | 375 μs |
| Smallest Potential Step for Sweep Voltammetry | 0.003% (30.52 ppm) of range, 300 μV min |
| Square Wave Voltammetry Max Frequency | 1 kHz (-1 V to +1V) |
| Power Supply Requirements | 100 – 240 VAC, 50 – 60 Hz |
Potentiostatic Input/Output
| Compliance Voltage | ±12 V |
| Voltage Scan Range | ±10 V |
| Number of Voltage Ranges | 1 range, [±10 V] |
| Applied Voltage Accuracy | 0.1% of setpoint, 2 mV min |
| Applied Voltage Resolution | 0.003% (30.52 ppm) of range , 300 μV min |
| Measured Voltage Accuracy | 0.1% of measured, 1 mV min |
| Measured Voltage Resolution | 0.003% (30.52 ppm) of range , 300 μV min |
| Time Resolution | 10 ns |
| iR Compensation Limits | 1.82 V max |
-
Galvanostatic Input/Output
Current Range ±100 mA Number of Current Ranges 8 ranges, [10 nA to 100 mA] Applied Current Accuracy 0.1% of range, 1 nA min Applied Current Resolution 0.003% (30.52 ppm) of range, 300 fA min Measured Current Accuracy 0.1% of range, 1 nA min Measured Current Resolution 0.003% (30.52 ppm) of range, 300 fA min